Difference between revisions of "Reading Neuroscan Files"
m |
|||
(5 intermediate revisions by 2 users not shown) | |||
Line 2: | Line 2: | ||
|title = Module information | |title = Module information | ||
|module = BESA Research | |module = BESA Research | ||
− | |version = 5.3 or higher | + | |version = BESA Research 5.3 or higher |
}} | }} | ||
BESA provides a file format reader that allows importing Neuroscan data in BESA Research. | BESA provides a file format reader that allows importing Neuroscan data in BESA Research. | ||
− | |||
Supported file format versions are | Supported file format versions are | ||
− | * Neuroscan Version 3.x ( | + | * Neuroscan Version 3.x (extensions: .cnt, .avg) |
− | * NeuroScan Curry 6 and 7 ( | + | * NeuroScan Curry 6 and 7 (extensions: .rs3 .dap .dat .ce*) (''this feature requires BESA Research 7.0 or higher'') |
+ | |||
+ | == Installation of file format readers == | ||
+ | |||
+ | * The data reader for Neuroscan Version 3.x is already installed by default. | ||
+ | * To install the reader for NeuroScan Curry 6 and 7 data, run the '''InstallReader.exe''' application in the '''Utilities\Additional Readers\Curry7\''' subfolder of your BESA Research installation (''this feature requires BESA Research 7.0 or higher''). | ||
+ | |||
+ | == FAQ == | ||
+ | |||
+ | === Reading 16-bit vs. 32-bit Neuroscan data files === | ||
+ | |||
+ | Neuroscan stores data either in 16-bit or 32-bit representation, but does not say so in the file format. So there is a setting in the ''BESA.ini'' file that can be set or adapted in section <code>[Defaults]</code>: | ||
+ | |||
+ | <source lang="text"> | ||
+ | NeuroScanDataNumberOfBits=32 | ||
+ | </source> | ||
− | + | This defines the format of NeuroScan data files ('16' for 16-bit; '32' for 32-bit). If this variable is not specified, BESA uses a heuristic to (try to) decide which of the two data formats is used. This variable overrides the heuristic. If you want to specify the NeuroScan data format for specific files, create a file, named "16bit" or "32bit", and place it in the data folder. | |
− | + | ||
− | + | ||
+ | Also see the Wiki page on the BESA.ini file for more details: [[The Initialization File: BESA.ini]] | ||
− | |||
[[Category:Data Import/Export]] | [[Category:Data Import/Export]] |
Latest revision as of 14:31, 5 May 2021
Module information | |
Modules | BESA Research |
Version | BESA Research 5.3 or higher |
BESA provides a file format reader that allows importing Neuroscan data in BESA Research.
Supported file format versions are
- Neuroscan Version 3.x (extensions: .cnt, .avg)
- NeuroScan Curry 6 and 7 (extensions: .rs3 .dap .dat .ce*) (this feature requires BESA Research 7.0 or higher)
Installation of file format readers
- The data reader for Neuroscan Version 3.x is already installed by default.
- To install the reader for NeuroScan Curry 6 and 7 data, run the InstallReader.exe application in the Utilities\Additional Readers\Curry7\ subfolder of your BESA Research installation (this feature requires BESA Research 7.0 or higher).
FAQ
Reading 16-bit vs. 32-bit Neuroscan data files
Neuroscan stores data either in 16-bit or 32-bit representation, but does not say so in the file format. So there is a setting in the BESA.ini file that can be set or adapted in section [Defaults]
:
NeuroScanDataNumberOfBits=32
This defines the format of NeuroScan data files ('16' for 16-bit; '32' for 32-bit). If this variable is not specified, BESA uses a heuristic to (try to) decide which of the two data formats is used. This variable overrides the heuristic. If you want to specify the NeuroScan data format for specific files, create a file, named "16bit" or "32bit", and place it in the data folder.
Also see the Wiki page on the BESA.ini file for more details: The Initialization File: BESA.ini