Difference between revisions of "Paradigm File Format in BESA"

From BESA® Wiki
Jump to: navigation, search
(Filter)
 
(49 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 +
{{BESAInfobox
 +
|title = Module information
 +
|module = BESA Research Basic or higher
 +
|version = BESA Research 5.2 or higher
 +
}}
  
 
== General remarks ==
 
== General remarks ==
Line 7: Line 12:
  
 
The PDG file is written in ASCII format and can thus be viewed and edited in any text editor. It is subdivided into a maximum of 9 sections:
 
The PDG file is written in ASCII format and can thus be viewed and edited in any text editor. It is subdivided into a maximum of 9 sections:
# [Attributes] Attributes which are used to group the trigger events. This section is mandatory.
+
 
# [Values] A table of attribute values which are defined for the triggers used in the experiment.
+
<blockquote style="background-color: #f9f9f9; border: solid thin lightgrey;">
# [Names] Names of conditions which are defined in detail in section 8
+
{|
# [Epochs] For each condition, averaging epochs, baseline epochs, and some other epochs are defined
+
|-
# [Thresholds] Threshold settings used for artifact rejection
+
| width="140pt" | [Attributes] || Attributes which are used to group the trigger events. This section is mandatory.
# [Averaging] Defines which conditions are selected for averaging
+
|-
# [Filter] Filter settings for averaging
+
| [Values] || A table of attribute values which are defined for the triggers used in the experiment.
# [TimeFrequency] Settings for time-frequency analysis
+
|-
# [Selections] Each condition is written here as a statement using Boolean logic  
+
| [Names] || Names of conditions which are defined in detail in section 8
# [ArtifactScan] The artifact scan results are written here
+
|-
 +
| [Epochs] || For each condition, averaging epochs, baseline epochs, and some other epochs are defined.
 +
|-
 +
| [Thresholds] || Threshold settings used for artifact rejection
 +
|-
 +
| [Averaging] || Defines which conditions are selected for averaging
 +
|-
 +
| [Filter] || Filter settings for averaging
 +
|-
 +
| [TimeFrequency] || Settings for time-frequency analysis
 +
|-
 +
| [Selections] || Each condition is written here as a statement using Boolean logic.
 +
|-
 +
| [ArtifactScan] || The artifact scan results are written here.
 +
|}
 +
</blockquote>
  
 
Most sections can be omitted; their entries are then filled with default values. The default settings are given in the detailed description (see below). The most relevant sections for describing an experiment are '''Attributes''', '''Values''', and '''Selections'''.
 
Most sections can be omitted; their entries are then filled with default values. The default settings are given in the detailed description (see below). The most relevant sections for describing an experiment are '''Attributes''', '''Values''', and '''Selections'''.
Line 32: Line 52:
  
 
== Detailed description of the sections ==
 
== Detailed description of the sections ==
 +
 
=== Attributes ===
 
=== Attributes ===
 
This section is mandatory.
 
This section is mandatory.
 
It holds the attributes which are used to group the trigger events. The first attribute is always the trigger code (“code”). Attributes are separated by a tabulator. By default, the ERP module defines a second attribute “name” which can take trigger names as attribute values.
 
It holds the attributes which are used to group the trigger events. The first attribute is always the trigger code (“code”). Attributes are separated by a tabulator. By default, the ERP module defines a second attribute “name” which can take trigger names as attribute values.
  
'''Example:'''
+
Example:
 
<source lang="dos">
 
<source lang="dos">
 
[Attributes]
 
[Attributes]
 
code name modality
 
code name modality
 
</source>
 
</source>
 +
 
=== Values ===
 
=== Values ===
 
This section holds a table of attribute values which are defined for the triggers used in the experiment. Each row defines one trigger. The first column holds the trigger codes, since the trigger code is the only mandatory attribute. The second column holds the values for the second attribute (default in the ERP module: name), and so on. If no value is defined for an attribute, “NULL” is entered. For trigger codes which are not listed, no values are defined.
 
This section holds a table of attribute values which are defined for the triggers used in the experiment. Each row defines one trigger. The first column holds the trigger codes, since the trigger code is the only mandatory attribute. The second column holds the values for the second attribute (default in the ERP module: name), and so on. If no value is defined for an attribute, “NULL” is entered. For trigger codes which are not listed, no values are defined.
  
'''Example:'''
+
Example:
 
<source lang="dos">
 
<source lang="dos">
 
[Values]
 
[Values]
Line 58: Line 80:
 
This section holds the names of conditions which are defined in detail in the section “Selections”. It is not necessary to give names to conditions. By default, conditions are simply named “Condition 1” through “Condition 32”. If a name is given, it is followed by the zero-based index of the condition it refers to. This enables mixing of conditions with user-given names and conditions with default names.
 
This section holds the names of conditions which are defined in detail in the section “Selections”. It is not necessary to give names to conditions. By default, conditions are simply named “Condition 1” through “Condition 32”. If a name is given, it is followed by the zero-based index of the condition it refers to. This enables mixing of conditions with user-given names and conditions with default names.
  
'''Example:'''
+
Example:
 
<source lang="dos">
 
<source lang="dos">
 
[Names]
 
[Names]
Line 70: Line 92:
 
This section holds the averaging epochs for each condition. Furthermore, additional epochs can be specified. Each epoch is defined by a floating point value which gives the pre-stimulus interval in milliseconds (ms), and a second floating point value which gives the post-stimulus interval in ms. Epochs are given in the following order:
 
This section holds the averaging epochs for each condition. Furthermore, additional epochs can be specified. Each epoch is defined by a floating point value which gives the pre-stimulus interval in milliseconds (ms), and a second floating point value which gives the post-stimulus interval in ms. Epochs are given in the following order:
  
'''Averaging epoch:''' The epoch used for averaging
+
* '''Averaging epoch''': The epoch used for averaging
 
+
* '''Baseline epoch''': The epoch over which the baseline is calculated
'''Baseline epoch:''' The epoch over which the baseline is calculated
+
* '''Epoch used for artifact rejection''': The epoch in which the data are checked for artifacts
 
+
* '''Stimulus artifact epoch''': An epoch where a stimulus artifact occurred. This epoch is interpolated over before artifact rejection takes place
'''Epoch used for artifact rejection:''' The epoch in which the data are checked for artifacts
+
* '''Stimulus delay''': Only one value. This value gives the delay of the stimulus relative to the trigger event (e.g. when tactile stimulation is performed, where air pressure builds up after the trigger was set).
 
+
'''Stimulus artifact epoch:''' An epoch where a stimulus artifact occurred. This epoch is interpolated over before artifact rejection takes place
+
 
+
'''Stimulus delay:''' Only one value. This value gives the delay of the stimulus relative to the trigger event (e.g. when tactile stimulation is performed, where air pressure builds up after the trigger was set).
+
  
 
Not all epochs have to be provided. If the epochs list for a condition is incomplete, default values are used.
 
Not all epochs have to be provided. If the epochs list for a condition is incomplete, default values are used.
Line 110: Line 128:
 
|}
 
|}
  
'''Example:'''
+
Example:
 
<source lang="dos">
 
<source lang="dos">
 
[Epochs]
 
[Epochs]
Line 117: Line 135:
 
</source>
 
</source>
  
The first condition is averaged from 500ms before the trigger event to 1000ms after the trigger event. Baseline is calculated in the pre-stimulus interval between 100ms before the trigger event and the trigger event. Artifacts are rejected between –500ms and +1000ms, i.e. over the entire averaging epoch. No stimulus artifact interval and no stimulus delay is given.
+
The first condition is averaged from 500 ms before the trigger event to 1000 ms after the trigger event. Baseline is calculated in the pre-stimulus interval between 100 ms before the trigger event and the trigger event. Artifacts are rejected between –500 ms and +1000 ms, i.e. over the entire averaging epoch. No stimulus artifact interval and no stimulus delay is given.
  
For the second condition, averaging and artifact rejection are set to –800...500 ms, and baseline calculation is performed in the interval from –800ms to –700ms. Again, no stimulus artifact interval, and no stimulus delay is given.
+
For the second condition, averaging and artifact rejection are set to –800...500 ms, and baseline calculation is performed in the interval from –800 ms to –700 ms. Again, no stimulus artifact interval, and no stimulus delay is given.
  
 
=== Thresholds ===
 
=== Thresholds ===
 
This section holds values for artifact rejection. It can hold two sets of values. The first set contains settings for the color normalization of the BESA artifact scan tool. These values are not directly used for artifact rejection, but merely for visual control if the BESA artifact scan tool is used for artifact rejection.  
 
This section holds values for artifact rejection. It can hold two sets of values. The first set contains settings for the color normalization of the BESA artifact scan tool. These values are not directly used for artifact rejection, but merely for visual control if the BESA artifact scan tool is used for artifact rejection.  
  
The line following the first set of values contains either the string “AUTO_REJECT”, or “MANUAL_REJECT”.  
+
The line following the first set of values contains either the string <code>AUTO_REJECT</code>, or <code>MANUAL_REJECT</code>.
The second set contains settings for automatic rejection of artifacts. It is used if the preceding line contains the string “AUTO_REJECT”. Otherwise, only artifacts which were manually marked in the data are excluded from the averaging process.
+
The second set contains settings for automatic rejection of artifacts. It is used if the preceding line contains the string <code>AUTO_REJECT</code>. Otherwise, only artifacts which were manually marked in the data are excluded from the averaging process.
  
 
The following table gives the order of the entries in the thresholds section:
 
The following table gives the order of the entries in the thresholds section:
Line 182: Line 200:
 
The unit &part;T stands for the sampling interval.
 
The unit &part;T stands for the sampling interval.
  
'''Example:'''
+
Example:
 
<source lang="dos">
 
<source lang="dos">
 
[Thresholds]
 
[Thresholds]
Line 247: Line 265:
 
If more than one bit is set, a different averaging buffer will be created for each sub-set.
 
If more than one bit is set, a different averaging buffer will be created for each sub-set.
  
'''Example:'''
+
Example:
 
<source lang="dos">
 
<source lang="dos">
 
[Averaging]
 
[Averaging]
Line 255: Line 273:
  
 
One condition was selected. The second condition (condition index 1) is selected and activated, and two buffers will be averaged: the first buffer for all matching sweeps (bit 0 set), the second buffer for the first half of matching sweeps (bit 3 set).
 
One condition was selected. The second condition (condition index 1) is selected and activated, and two buffers will be averaged: the first buffer for all matching sweeps (bit 0 set), the second buffer for the first half of matching sweeps (bit 3 set).
 +
 
=== Filter ===
 
=== Filter ===
 
This section holds filter settings which were chosen for averaging. The following table gives the possible settings.
 
This section holds filter settings which were chosen for averaging. The following table gives the possible settings.
Line 321: Line 340:
 
| TRUE if high pass filter applied to artifact scan,  
 
| TRUE if high pass filter applied to artifact scan,  
 
FALSE if not
 
FALSE if not
|  
+
| TRUE if low pass filter applied to artifact scan,
 +
FALSE if not
 
|  
 
|  
 
|  
 
|  
Line 344: Line 364:
 
| 48
 
| 48
 
|}
 
|}
 +
 +
{| class="wikitable"
 +
! style="font-weight: bold;" | Type value in file
 +
! style="font-weight: bold;" | Corresponding filter type
 +
|-
 +
| 0
 +
| Zero phase
 +
|-
 +
| 1
 +
| Forward
 +
|-
 +
| 2
 +
| Backward
 +
|}
 +
 +
If any of the required settings are missing, the filters that are currently set in the data file are used for averaging.
 +
 +
Example:
 +
<source lang="dos">
 +
[Filter]
 +
0.200000 0 1 1
 +
75.000000 1 0 0
 +
0.000000 1.000000 FALSE
 +
75.000000 7.500000 FALSE
 +
FALSE FALSE
 +
FALSE FALSE FALSE
 +
TRUE FALSE
 +
</source>
 +
 +
The filters are set as follows:
 +
 +
High pass at 0.2 Hz, 6 db/Oct, forward filtering, activated.
 +
 +
Low pass at 75.0 Hz, 12 db/Oct, zero phase filtering, not activated
 +
 +
Notch filter at 0 Hz, width 1 Hz, not activated
 +
 +
Band pass filter at 75 Hz, width 7.5 Hz, not activated
 +
 +
Polygraphic channels are filtered like the EEG and MEG channels. They are not rectified.
 +
 +
Selected channels are not differentiated, not rectified, and not smoothed.
 +
 +
High pass filter is also activated for the artifact scan, and low pass filter is not activated for the artifact scan.
 +
 +
So, the only filter that will be applied to the data for both averaging and artifact scan is the high pass filter at 0.2 Hz.
 +
 +
The last line holds activation settings for the artifact scan. Thus, it is possible to activate or de-activate filters solely for the artifact scan.
 +
 +
=== TimeFrequency ===
 +
This section holds the settings of the Time-Frequency dialog. It is only read if the time-frequency module is loaded. The following values are stored:
 +
 +
{| class="wikitable"
 +
! style="font-weight: bold;" | Line #
 +
! style="font-weight: bold;" | First column
 +
! style="font-weight: bold;" | Second column
 +
! style="font-weight: bold;" | Third column
 +
|-
 +
| 1
 +
| ID for analysis type:
 +
0: time-frequency
 +
1: mean coherence
 +
2: coherence
 +
| ID for coherence computation type:
 +
2: fixed reference channel
 +
6: any reference channel. Currently,
 +
this value is always used.
 +
| Channel index in case a fixed
 +
reference channel was used. Currently,
 +
this value is meaningless.
 +
|-
 +
| 2
 +
| Reduced sampling interval (in microseconds)
 +
after time-frequency transformation
 +
|
 +
|
 +
|-
 +
| 3
 +
| Index of the condition which
 +
was chosen as target condition
 +
| TRUE if a control condition was specified,
 +
FALSE if not
 +
| Index of the control condition if a
 +
control condition was specified,
 +
or -1 if no condition was specified
 +
|-
 +
| 4
 +
| ID for option of regional source usage:
 +
0: radial orientation (not available for MEG)
 +
1: all traces are taken
 +
2: orientation which maximizes power is taken (not yet available)
 +
3: first orientation is taken (interesting for oriented sources)
 +
| TRUE if a Gaussian FIR filter is used
 +
for complex demodulation (default),
 +
FALSE if a non-Gaussian FIR filter is used
 +
for complex demodulation
 +
|
 +
|-
 +
| 5
 +
| Index for the frequency spacing
 +
that is used (index of the array entry
 +
in the combo box array of the dialog box)
 +
| ID for bandwidth of the
 +
demodulation filter that was chosen.
 +
2: 2 frequency spacings
 +
4: 4 frequency spacings (default)
 +
|
 +
|-
 +
| 6
 +
| ID for lower frequency cutoff index
 +
(index of the array entry in the combo box
 +
array of the dialog box)
 +
| Value of lower frequency cutoff in Hz
 +
| ID for higher frequency cutoff (index
 +
of the array entry in the combo box array
 +
of the dialog box)
 +
|-
 +
| 7
 +
| ID for the range in which mean coherence is
 +
computed (currently not used):
 +
1: whole data set
 +
2: all epochs
 +
3: epochs with a specific label
 +
| ID of the epoch which was chosen for mean
 +
coherence computation (currently not used)
 +
|
 +
|}
 +
 +
Example:
 +
<source lang="dos">
 +
[TimeFrequency]
 +
2 6 0
 +
25000.000000
 +
2 FALSE -1
 +
0 TRUE
 +
4 4
 +
3 4.000000 6
 +
1 0
 +
</source>
 +
In this example, the values have the following meaning:
 +
 +
1st line: Coherence analysis with any reference channel possible.
 +
 +
2nd line: The reduced sampling interval after Time-frequency transformation is 25 ms, i.e. 25000 µs.
 +
 +
3rd line: Target condition has condition index 2, no control condition was specified.
 +
 +
4th line: For regional sources, the radial orientation is taken. The Gaussian FIR filter is used.
 +
 +
5th line: Array entry with index 4 was chosen for the frequency spacing. The demodulation filter is calculated for a bandwidth of 4 frequency spacings.
 +
 +
6th line: Array entry with index 3 was chosen for the lower frequency cutoff. The lower cutoff frequency is 4 Hz. Array entry with index 6 was chosen for the higher frequency cutoff.
 +
 +
7th line: (currently not used) For mean coherence analysis, the whole data set is used. The epoch length of each epoch is given by array index 0.
 +
 +
=== Selections ===
 +
This section holds the definition of conditions in boolean logic. Each line corresponds to either a logic statement, a bracket, or a boolean operator. Conditions are separated by blank lines. There are no default settings for this section.
 +
 +
Tokens are written in uppercase.
 +
 +
A statement consists of
 +
* a qualifier that can be either CURRENT, PREVIOUS, or NEXT depending on which trigger event is tested
 +
* an attribute (e.g. code, name, interval, ...)
 +
* a comparison operator (IS, IS NOT, IS MORE THAN, IS LESS THAN)
 +
* a value (e.g. “tone”, 300ms, ...)
 +
Operators can be AND, OR. Bracketing is also possible.
 +
 +
Example:
 +
<source lang="dos">
 +
[Selections]
 +
CURRENT.name IS "tone"
 +
 +
CURRENT.name IS "response"
 +
AND
 +
PREVIOUS.name IS "tone"
 +
AND
 +
PREVIOUS.interval IS LESS THAN 300ms
 +
 +
CURRENT.name IS "response"
 +
AND
 +
(
 +
PREVIOUS.name IS "rare"
 +
OR
 +
PREVIOUS.name IS "frequent"
 +
)
 +
</source>
 +
 +
This example contains 3 conditions.
 +
 +
The first one selects all trigger events with the value “tone” for the attribute “name”.
 +
 +
The second one selects all trigger events with the value “response” for the attribute “name” which are preceded by trigger events with the name “tone” with an interval between the two of less than 300ms.
 +
 +
The third one selects all trigger events with the name “response” which are preceded by either a trigger event with the name “rare” or a trigger event with the name “frequent”. The bracket is important; without the bracket, the order of testing is changed, with a possibly different result.
 +
 +
=== Artifact Scan ===
 +
This section holds the results of an artifact scan. They are plotted in the artifact tab central window. For each epoch which was scanned, all values are written. The format contains 4 header lines, followed by 4 lines for each epoch:
 +
 +
<blockquote style="background-color: #f9f9f9; border: solid thin lightgrey;">
 +
 +
Line 1: <Number of EEG channels> <Number of magnetometer or axial gradiometer channels> <Number of planar gradiometer channels>
 +
 +
Line 2: <Channel badness flag for channel 1> <Channel badness flag for channel 2> … <Channel badness flag for channel N>
 +
 +
The channel badness flag is set as follows:
 +
 +
{| class="wikitable"
 +
! style="font-weight: bold;" | 0
 +
! style="font-weight: bold;" | not bad or bad due to user interaction
 +
|-
 +
| bit 0 set:
 +
| bad due to minimum signal/variance crit., max.
 +
|-
 +
| bit 1 set:
 +
| bad due to amplitude criterion, integral crit.
 +
|-
 +
| bit 2 set:
 +
| bad due to amplitude criterion, max. crit.
 +
|-
 +
| bit 3 set:
 +
| bad due to gradient criterion, integral crit.
 +
|-
 +
| bit 4 set:
 +
| bad due to gradient criterion, max. crit.
 +
|-
 +
| bit 5 set:
 +
| bad due to minimum signal/variance crit., int.
 +
|}
 +
 +
Line 3: <Number of conditions><index of first condition in list><index of 2nd condition in list>…<index of last condition in list>
 +
 +
The list is the artifact scan list of conditions.
 +
 +
Line 4: <Start of scanned range (position in microseconds)><end of scanned range (position in microseconds>
 +
</blockquote>
 +
 +
 +
The remaining lines come in groups of 4. Each group contains the settings for one epoch. For each epoch:
 +
 +
<blockquote style="background-color: #f9f9f9; border: solid thin lightgrey;">
 +
 +
Line 1: <artifact scan list index><position in microseconds>
 +
 +
The artifact scan list index is not necessarily the same as the condition index. It is possible that no artifact scan list index exists for a condition index, e.g. if no matches were found for a condition. The artifact scan list index runs from 0 to the number of conditions for which a scan was performed. The relation to the real condition index is given by the header line 3.
 +
 +
Line 2: <max_amp_in_channel1>< max_amp_in_channel2>…< max_amp_in_channelN>
 +
 +
Line 3: <variance_in_channel1><variance_in_channel2>…<variance_in_channelN>
 +
 +
Line 4: <max_gradient_in_channel1>< max_gradient_in_channel2>…< max_gradient_in_channelN>
 +
</blockquote>
 +
 +
 +
Example:
 +
 +
Please note that one color denotes one line in the PDG-file.
 +
 +
<blockquote style="background-color: #f9f9f9; border: solid thin lightgrey;">
 +
 +
[ArtifactScan]
 +
 +
{{font color|blue|65 0 0}}
 +
 +
{{font color|red|0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0}}
 +
 +
{{font color|red|0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0}}
 +
 +
{{font color|red|0 0 0 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0}}
 +
 +
{{font color|red|0 0 0 0 0}}
 +
 +
{{font color|deeppink|2 1 2}}
 +
 +
{{font color|green|0.000000 319120000.000000}}
 +
 +
{{font color|blue|0 7700000.00}}
 +
 +
{{font color|red|6.71 18.46 44.48 23.50 48.68 24.34 60.42 13.43 20.14 44.48 21.82 60.42 25.18 62.94 15.11 35.25 18.46 36.93 51.19 32.73 41.96 16.78 35.25}}
 +
 +
{{font color|red|20.14 26.02 4.20 35.25 12.59 35.25 21.82 33.57 21.82 7.55 15.95 34.41 31.89 31.89 16.78 27.69 28.53 36.09 11.75 29.37 46.16 19.30 24.34 10.91}}
 +
 +
{{font color|red|26.86 19.30 31.05 7.55 22.66 36.93 33.57 37.77 27.69 21.82 10.91 28.53 34.41 48.68 27.69 27.69 15.95 0.00}}
 +
 +
{{font color|deeppink|1.04 5.87 14.84 4.36 13.35 4.95 12.75 3.38 5.63 13.72 3.78 17.54 4.54 13.11 2.97 14.77 2.69 16.07 10.95 8.41 8.39 4.74 14.73 1.92 6.49 0.65}}
 +
 +
{{font color|deeppink|7.46 1.51 15.48 3.92 9.27 4.01 0.89 3.29 10.13 9.02 11.43 3.75 6.81 6.77 7.77 1.39 9.51 25.05 4.51 6.36 1.27 5.50 4.19 10.37 0.91 5.93 11.32}}
 +
 +
{{font color|deeppink|8.88 9.77 9.11 6.51 1.79 7.68 10.50 14.24 8.82 8.22 2.95 0.00}}
 +
 +
{{font color|green|2.52 6.71 10.07 5.04 8.39 5.04 10.07 4.20 6.71 11.75 5.04 12.59 5.04 9.23 5.04 10.07 4.20 10.07 8.39 7.55 8.39 5.87 11.75 3.36 5.04 1.68}}
 +
 +
{{font color|green|7.55 2.52 10.91 5.04 6.71 5.04 2.52 5.04 12.59 11.75 14.27 5.87 6.71 6.71 7.55 2.52 13.43 15.11 5.87 8.39 3.36 7.55 8.39 13.43 2.52 8.39}}
 +
 +
{{font color|green|10.07 7.55 8.39 10.91 9.23 4.20 6.71 13.43 11.75 11.75 10.91 6.71 0.00}}
 +
 +
{{font color|blue|1 8050000.00}}
 +
 +
{{font color|red|8.39 15.95 35.25 21.82 22.66 19.30 26.86 12.59 17.62 31.89 21.82 20.98 17.62 26.86 15.11 23.50 16.78 30.21 29.37 22.66 22.66 16.78 22.66}}
 +
 +
{{font color|red|15.95 23.50 5.87 22.66 13.43 25.18 19.30 26.86 17.62 6.71 11.75 20.14 19.30 23.50 14.27 27.69 21.82 20.98 9.23 20.14 64.62 17.62 23.50 8.39 15.11 15.11 21.82}}
 +
 +
{{font color|red|6.71 20.98 29.37 24.34 20.98 16.78 17.62 11.75 25.18 26.86 24.34 20.98 21.82 15.11 0.00}}
 +
 +
{{font color|deeppink|1.37 6.08 14.32 7.01 11.00 7.54 11.19 3.85 7.11 13.96 6.67 12.18 7.18 10.64 5.47 16.83 3.79 21.73 9.60 12.82 9.11 5.45 12.86 3.74 8.62}}
 +
 +
{{font color|deeppink|0.83 9.30 2.92 14.68 5.85 13.81 5.18 1.28 3.44 8.30 7.25 12.03 4.16 8.80 9.74 7.23 1.76 8.49 56.16 5.41 7.29 1.70 4.96 4.45 9.66 1.35}}
 +
 +
{{font color|deeppink|7.16 12.32 10.99 8.29 6.38 6.61 2.07 8.25 13.16 8.23 8.70 8.71 4.44 0.00}}
 +
 +
{{font color|green|2.52 6.71 10.91 8.39 9.23 8.39 9.23 6.71 6.71 10.91 8.39 9.23 8.39 9.23 5.87 11.75 5.04 12.59 9.23 10.91 7.55 5.87 11.75 5.87 8.39 2.52}}
 +
 +
{{font color|green|7.55 5.87 9.23 6.71 11.75 6.71 3.36 4.20 7.55 7.55 10.07 5.87 9.23 7.55 7.55 3.36 7.55 28.53 7.55 8.39 3.36 5.87 5.87 9.23 3.36 9.23 9.23}}
 +
 +
{{font color|green|7.55 6.71 7.55 7.55 4.20 9.23 11.75 7.55 8.39 8.39 7.55 0.00}}
 +
</blockquote>
 +
 +
This example contains the first 2 epochs from an artifact scan.
 +
 +
 +
{{font color|blue|65 0 0}}
 +
 +
This line shows the number of EEG (65), MAG and GRA channels.
 +
 +
 +
{{font color|red|0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0}}
 +
 +
{{font color|red|0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0}}
 +
 +
{{font color|red|0 0 0 0 0 0 0 8 0 0 0 0 0 0 0 0 0 0}}
 +
 +
{{font color|red|0 0 0 0 0 0 0 0 0 0 0}}
 +
 +
This line shows the badness of the channels. One channel has badness 8, which stands for gradient and integral criterion.
 +
 +
 +
{{font color|deeppink|2 1 2}}
 +
 +
This line states the number of conditions in the artifact scan list, and their indices: There are 2 conditions; the list element 0 contains condition 1, list element 1 contains condition 2. Condition 0 is not part of the scan.
 +
 +
 +
{{font color|green|0.000000 319120000.000000}}
 +
 +
A range from 0 – 319.120 seconds was scanned.
 +
The next lines give the values for the epochs in groups of 4:
 +
 +
 +
{{font color|blue|0 7700000.00}}
 +
 +
This entry has artifact list index 0 (which corresponds to condition index 1, see above), and the position of the epoch is 7.700000 seconds.
 +
 +
 +
The next 3 lines hold amplitudes, variances, and gradients for each channel.
 +
 +
 +
[[Category:ERP/ERF]] [[Category:Data Import/Export]]

Latest revision as of 07:38, 6 May 2021

Module information
Modules BESA Research Basic or higher
Version BESA Research 5.2 or higher

General remarks

A paradigm description file (“PDG file”) contains the information which is relevant for describing an experimental setup in terms of the stimulation and response events that occurred. To describe the experimental paradigm, three terms are introduced:

  1. An attribute is used to group trigger events into a certain class. For example, in an auditory experiment, triggers could be grouped according to an attribute “modality” to distinguish stimulation and response, and another attribute “side” to distinguish left and right.
  2. An attribute value defines how a trigger event is classified in the class defined by an attribute. For example, the trigger with the code 1 could be a tone stimulus, and the trigger with the code 2 could be the subject’s response. That means that for the “modality” attribute, trigger 1 would receive an attribute value “tone”, whereas trigger 2 would receive an attribute value “response”.
  3. A condition defines which trigger events form the set of events that should be averaged. For example, this could simply be all trigger events with the modality “tone”, or all trigger events which have the modality “response”, and follow a trigger event with the modality “tone”.

The PDG file is written in ASCII format and can thus be viewed and edited in any text editor. It is subdivided into a maximum of 9 sections:

[Attributes] Attributes which are used to group the trigger events. This section is mandatory.
[Values] A table of attribute values which are defined for the triggers used in the experiment.
[Names] Names of conditions which are defined in detail in section 8
[Epochs] For each condition, averaging epochs, baseline epochs, and some other epochs are defined.
[Thresholds] Threshold settings used for artifact rejection
[Averaging] Defines which conditions are selected for averaging
[Filter] Filter settings for averaging
[TimeFrequency] Settings for time-frequency analysis
[Selections] Each condition is written here as a statement using Boolean logic.
[ArtifactScan] The artifact scan results are written here.

Most sections can be omitted; their entries are then filled with default values. The default settings are given in the detailed description (see below). The most relevant sections for describing an experiment are Attributes, Values, and Selections.

Connection to BESA paradigm editing tool: Sections 1 and 2 define entries in the “Trigger” tab. Sections 3 and 9 define entries in the “Condition” tab. Section 4 defines entries in the “Epoch” tab. Sections 5 and 10 define entries in the “Artifact” tab. Section 6 defines entries in the “Average” tab. Section 7 defines entries in the “Filter” tab. Section 8 defines entries in the “Coherence” tab (if available).

All values can be edited in the respective tabs of the paradigm editing tool.

Detailed description of the sections

Attributes

This section is mandatory. It holds the attributes which are used to group the trigger events. The first attribute is always the trigger code (“code”). Attributes are separated by a tabulator. By default, the ERP module defines a second attribute “name” which can take trigger names as attribute values.

Example:

[Attributes]
code	name	modality

Values

This section holds a table of attribute values which are defined for the triggers used in the experiment. Each row defines one trigger. The first column holds the trigger codes, since the trigger code is the only mandatory attribute. The second column holds the values for the second attribute (default in the ERP module: name), and so on. If no value is defined for an attribute, “NULL” is entered. For trigger codes which are not listed, no values are defined.

Example:

[Values]
0	NULL	NULL
1	tone	auditory
2	rare	auditory
3	frequent	auditory
128	response	motor

The trigger with code 0 has no values defined, the trigger with code 1 has the name “tone” and the modality “auditory”, and so on.

Names

This section holds the names of conditions which are defined in detail in the section “Selections”. It is not necessary to give names to conditions. By default, conditions are simply named “Condition 1” through “Condition 32”. If a name is given, it is followed by the zero-based index of the condition it refers to. This enables mixing of conditions with user-given names and conditions with default names.

Example:

[Names]
target	0
hit	1

The first condition obtains the name “target”, the second one obtains the name “hit”.

Epochs

This section holds the averaging epochs for each condition. Furthermore, additional epochs can be specified. Each epoch is defined by a floating point value which gives the pre-stimulus interval in milliseconds (ms), and a second floating point value which gives the post-stimulus interval in ms. Epochs are given in the following order:

  • Averaging epoch: The epoch used for averaging
  • Baseline epoch: The epoch over which the baseline is calculated
  • Epoch used for artifact rejection: The epoch in which the data are checked for artifacts
  • Stimulus artifact epoch: An epoch where a stimulus artifact occurred. This epoch is interpolated over before artifact rejection takes place
  • Stimulus delay: Only one value. This value gives the delay of the stimulus relative to the trigger event (e.g. when tactile stimulation is performed, where air pressure builds up after the trigger was set).

Not all epochs have to be provided. If the epochs list for a condition is incomplete, default values are used.

By default, the following values are used:

Epoch Pre-stimulus value Post-stimulus value
Averaging -100 500
Baseline -100 0
Artifact rejection -100 500
Stimulus artifact 0 0
Stimulus delay 0

Example:

[Epochs]
-500.0	1000.0	-100.0	0.0	-500.0	1000.0	0.0	0.0	0.0
-800.0	500.0	-800.0	-700.0	-800.0	500.0	0.0	0.0	0.0

The first condition is averaged from 500 ms before the trigger event to 1000 ms after the trigger event. Baseline is calculated in the pre-stimulus interval between 100 ms before the trigger event and the trigger event. Artifacts are rejected between –500 ms and +1000 ms, i.e. over the entire averaging epoch. No stimulus artifact interval and no stimulus delay is given.

For the second condition, averaging and artifact rejection are set to –800...500 ms, and baseline calculation is performed in the interval from –800 ms to –700 ms. Again, no stimulus artifact interval, and no stimulus delay is given.

Thresholds

This section holds values for artifact rejection. It can hold two sets of values. The first set contains settings for the color normalization of the BESA artifact scan tool. These values are not directly used for artifact rejection, but merely for visual control if the BESA artifact scan tool is used for artifact rejection.

The line following the first set of values contains either the string AUTO_REJECT, or MANUAL_REJECT. The second set contains settings for automatic rejection of artifacts. It is used if the preceding line contains the string AUTO_REJECT. Otherwise, only artifacts which were manually marked in the data are excluded from the averaging process.

The following table gives the order of the entries in the thresholds section:

Line # First column Second column
1 Max. amplitude in EEG [µV] (display) Max. amplitude in MEG [fT or fT/cm] (display)
2 Square root of variance of gradient in EEG (display) Square root of variance of gradient in MEG (display)
3 Max. gradient in EEG (display) Max. gradient in MEG (display)
4 AUTO_REJECT or MANUAL_REJECT
5 Max. amplitude in EEG [µV] (for rejection) Max. amplitude in MEG [fT or fT/cm] (for rejection)
6 Square root of variance of gradient in EEG (for rejection) Square root of variance of gradient in MEG (for rejection)
7 Max. gradient in EEG (for rejection) Max. gradient in MEG (for rejection)

If no values are given , the following values are used by default:

Threshold type EEG MEG
Max. amplitude 100 µV 1000 fT or fT/cm (depending on data)
Variance of gradient 0.001 µV/∂T 64 fT/∂T or 64 fT/(∂T cm) (depending on data)
Max. gradient 75 µV/∂T 800 fT/∂T or fT/(cm ∂T) (depending on data)

The unit ∂T stands for the sampling interval.

Example:

[Thresholds]
100.0	1000.0
0.001	64.000
75.0	800.0
AUTO_REJECT
100.0	1000.0
0.001	64.000
75.0	800.0

Automatic artifact rejection is active. The rejection thresholds are:

  • 100 µV for EEG amplitude,
  • 1000 fT for MEG amplitude,
  • µV/∂T for the square root of the variance of the gradient of the EEG signal,
  • 64 fT/∂T for the square root of the variance of the gradient of the MEG signal,
  • 75 µV/∂T for the gradient of the EEG amplitude, and
  • 800 fT/∂T for the gradient of the MEG amplitude.

The display thresholds for the BESA artifact scan tool are set to the same values.

Rejection behavior:

A sweep is rejected from averaging if:

  • The signal exceeds the max. amplitude threshold at any sampling point in any of the “good” channels.
  • The variance of the gradient of the signal, taken over the whole sweep, does not exceed the variance threshold in any of the “good” channels. This criteria is especially useful for MEG channels, where channels may show a flat signal temporarily during the measurement.
  • The gradient of the signal exceeds the max. gradient threshold at any sampling point in any of the “good” channels.

Averaging

This section holds the conditions which are selected for averaging, and further information about whether all sweeps or a sub-set will be averaged.

The first line holds the number of conditions currently selected (N). If N=0 or if the section is not present, all conditions which have at least 1 matching trigger event are automatically selected for averaging.

The next N lines are organized as follows:

Column 1: 1 if the condition is selected and activated, 0 if it is selected, but not activated.

Column 2: Zero-based index of the condition.

Column 3: Information about whether all sweeps or a sub-set will be averaged, encoded bit-wise:

Bit If set:
0 Average all matching sweeps
1 Average every second matching sweep (even)
2 Average every second matching sweep (odd)
3 Average the first half of matching sweeps
4 Average the second half of matching sweeps

If more than one bit is set, a different averaging buffer will be created for each sub-set.

Example:

[Averaging]
1
1	1	9

One condition was selected. The second condition (condition index 1) is selected and activated, and two buffers will be averaged: the first buffer for all matching sweeps (bit 0 set), the second buffer for the first half of matching sweeps (bit 3 set).

Filter

This section holds filter settings which were chosen for averaging. The following table gives the possible settings.

Line # Filter type Column 1 Column 2 Column 3 Column 4
1 High pass Frequency [Hz] Slope (see below) Type (see below) 1 if filter is applied,

0 if not applied

2 Low pass Frequency [Hz] Slope (see below) Type (see below) 1 if filter is applied,

0 if not applied

3 Notch Frequency [Hz] Width [Hz] TRUE if on,

FALSE if off

4 Band pass Frequency [Hz] Width [Hz] TRUE if on,

FALSE if off

5 Polygraphic channels TRUE if polygraphic channels unfiltered,

FALSE if filtered like EEG/MEG channels

TRUE if polygraphic channels rectified,

FALSE if not rectified

6 Selected channels TRUE if selected channels differentiated,

FALSE if not differentiated

TRUE if selected channels rectified,

FALSE if not rectified

TRUE if selected channels smoothed,

FALSE if not smoothed

7 High pass,

Low pass

TRUE if high pass filter applied to artifact scan,

FALSE if not

TRUE if low pass filter applied to artifact scan,

FALSE if not

The parameters Slope and Type are set to one of the following values:

Slope value in file Corresponding filter slope [dB/Oct]
0 6
1 12
2 24
3 48
Type value in file Corresponding filter type
0 Zero phase
1 Forward
2 Backward

If any of the required settings are missing, the filters that are currently set in the data file are used for averaging.

Example:

[Filter]
0.200000	0	1	1
75.000000	1	0	0
0.000000	1.000000	FALSE
75.000000	7.500000	FALSE
FALSE	FALSE
FALSE	FALSE	FALSE
TRUE		FALSE

The filters are set as follows:

High pass at 0.2 Hz, 6 db/Oct, forward filtering, activated.

Low pass at 75.0 Hz, 12 db/Oct, zero phase filtering, not activated

Notch filter at 0 Hz, width 1 Hz, not activated

Band pass filter at 75 Hz, width 7.5 Hz, not activated

Polygraphic channels are filtered like the EEG and MEG channels. They are not rectified.

Selected channels are not differentiated, not rectified, and not smoothed.

High pass filter is also activated for the artifact scan, and low pass filter is not activated for the artifact scan.

So, the only filter that will be applied to the data for both averaging and artifact scan is the high pass filter at 0.2 Hz.

The last line holds activation settings for the artifact scan. Thus, it is possible to activate or de-activate filters solely for the artifact scan.

TimeFrequency

This section holds the settings of the Time-Frequency dialog. It is only read if the time-frequency module is loaded. The following values are stored:

Line # First column Second column Third column
1 ID for analysis type:

0: time-frequency 1: mean coherence 2: coherence

ID for coherence computation type:

2: fixed reference channel 6: any reference channel. Currently, this value is always used.

Channel index in case a fixed

reference channel was used. Currently, this value is meaningless.

2 Reduced sampling interval (in microseconds)

after time-frequency transformation

3 Index of the condition which

was chosen as target condition

TRUE if a control condition was specified,

FALSE if not

Index of the control condition if a

control condition was specified, or -1 if no condition was specified

4 ID for option of regional source usage:

0: radial orientation (not available for MEG) 1: all traces are taken 2: orientation which maximizes power is taken (not yet available) 3: first orientation is taken (interesting for oriented sources)

TRUE if a Gaussian FIR filter is used

for complex demodulation (default), FALSE if a non-Gaussian FIR filter is used for complex demodulation

5 Index for the frequency spacing

that is used (index of the array entry in the combo box array of the dialog box)

ID for bandwidth of the

demodulation filter that was chosen. 2: 2 frequency spacings 4: 4 frequency spacings (default)

6 ID for lower frequency cutoff index

(index of the array entry in the combo box array of the dialog box)

Value of lower frequency cutoff in Hz ID for higher frequency cutoff (index

of the array entry in the combo box array of the dialog box)

7 ID for the range in which mean coherence is

computed (currently not used): 1: whole data set 2: all epochs 3: epochs with a specific label

ID of the epoch which was chosen for mean

coherence computation (currently not used)

Example:

[TimeFrequency]
2	6	0
25000.000000
2	FALSE	-1
0	TRUE
4	4
3	4.000000	6
1	0

In this example, the values have the following meaning:

1st line: Coherence analysis with any reference channel possible.

2nd line: The reduced sampling interval after Time-frequency transformation is 25 ms, i.e. 25000 µs.

3rd line: Target condition has condition index 2, no control condition was specified.

4th line: For regional sources, the radial orientation is taken. The Gaussian FIR filter is used.

5th line: Array entry with index 4 was chosen for the frequency spacing. The demodulation filter is calculated for a bandwidth of 4 frequency spacings.

6th line: Array entry with index 3 was chosen for the lower frequency cutoff. The lower cutoff frequency is 4 Hz. Array entry with index 6 was chosen for the higher frequency cutoff.

7th line: (currently not used) For mean coherence analysis, the whole data set is used. The epoch length of each epoch is given by array index 0.

Selections

This section holds the definition of conditions in boolean logic. Each line corresponds to either a logic statement, a bracket, or a boolean operator. Conditions are separated by blank lines. There are no default settings for this section.

Tokens are written in uppercase.

A statement consists of

  • a qualifier that can be either CURRENT, PREVIOUS, or NEXT depending on which trigger event is tested
  • an attribute (e.g. code, name, interval, ...)
  • a comparison operator (IS, IS NOT, IS MORE THAN, IS LESS THAN)
  • a value (e.g. “tone”, 300ms, ...)

Operators can be AND, OR. Bracketing is also possible.

Example:

[Selections]
CURRENT.name IS "tone"
 
CURRENT.name IS "response"
AND
PREVIOUS.name IS "tone"
AND
PREVIOUS.interval IS LESS THAN 300ms
 
CURRENT.name IS "response"
AND
(
PREVIOUS.name IS "rare"
OR
PREVIOUS.name IS "frequent"
)

This example contains 3 conditions.

The first one selects all trigger events with the value “tone” for the attribute “name”.

The second one selects all trigger events with the value “response” for the attribute “name” which are preceded by trigger events with the name “tone” with an interval between the two of less than 300ms.

The third one selects all trigger events with the name “response” which are preceded by either a trigger event with the name “rare” or a trigger event with the name “frequent”. The bracket is important; without the bracket, the order of testing is changed, with a possibly different result.

Artifact Scan

This section holds the results of an artifact scan. They are plotted in the artifact tab central window. For each epoch which was scanned, all values are written. The format contains 4 header lines, followed by 4 lines for each epoch:

Line 1: <Number of EEG channels> <Number of magnetometer or axial gradiometer channels> <Number of planar gradiometer channels>

Line 2: <Channel badness flag for channel 1> <Channel badness flag for channel 2> … <Channel badness flag for channel N>

The channel badness flag is set as follows:

0 not bad or bad due to user interaction
bit 0 set: bad due to minimum signal/variance crit., max.
bit 1 set: bad due to amplitude criterion, integral crit.
bit 2 set: bad due to amplitude criterion, max. crit.
bit 3 set: bad due to gradient criterion, integral crit.
bit 4 set: bad due to gradient criterion, max. crit.
bit 5 set: bad due to minimum signal/variance crit., int.

Line 3: <Number of conditions><index of first condition in list><index of 2nd condition in list>…<index of last condition in list>

The list is the artifact scan list of conditions.

Line 4: <Start of scanned range (position in microseconds)><end of scanned range (position in microseconds>


The remaining lines come in groups of 4. Each group contains the settings for one epoch. For each epoch:

Line 1: <artifact scan list index><position in microseconds>

The artifact scan list index is not necessarily the same as the condition index. It is possible that no artifact scan list index exists for a condition index, e.g. if no matches were found for a condition. The artifact scan list index runs from 0 to the number of conditions for which a scan was performed. The relation to the real condition index is given by the header line 3.

Line 2: <max_amp_in_channel1>< max_amp_in_channel2>…< max_amp_in_channelN>

Line 3: <variance_in_channel1><variance_in_channel2>…<variance_in_channelN>

Line 4: <max_gradient_in_channel1>< max_gradient_in_channel2>…< max_gradient_in_channelN>


Example:

Please note that one color denotes one line in the PDG-file.

[ArtifactScan]

65 0 0

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0

2 1 2

0.000000 319120000.000000

0 7700000.00

6.71 18.46 44.48 23.50 48.68 24.34 60.42 13.43 20.14 44.48 21.82 60.42 25.18 62.94 15.11 35.25 18.46 36.93 51.19 32.73 41.96 16.78 35.25

20.14 26.02 4.20 35.25 12.59 35.25 21.82 33.57 21.82 7.55 15.95 34.41 31.89 31.89 16.78 27.69 28.53 36.09 11.75 29.37 46.16 19.30 24.34 10.91

26.86 19.30 31.05 7.55 22.66 36.93 33.57 37.77 27.69 21.82 10.91 28.53 34.41 48.68 27.69 27.69 15.95 0.00

1.04 5.87 14.84 4.36 13.35 4.95 12.75 3.38 5.63 13.72 3.78 17.54 4.54 13.11 2.97 14.77 2.69 16.07 10.95 8.41 8.39 4.74 14.73 1.92 6.49 0.65

7.46 1.51 15.48 3.92 9.27 4.01 0.89 3.29 10.13 9.02 11.43 3.75 6.81 6.77 7.77 1.39 9.51 25.05 4.51 6.36 1.27 5.50 4.19 10.37 0.91 5.93 11.32

8.88 9.77 9.11 6.51 1.79 7.68 10.50 14.24 8.82 8.22 2.95 0.00

2.52 6.71 10.07 5.04 8.39 5.04 10.07 4.20 6.71 11.75 5.04 12.59 5.04 9.23 5.04 10.07 4.20 10.07 8.39 7.55 8.39 5.87 11.75 3.36 5.04 1.68

7.55 2.52 10.91 5.04 6.71 5.04 2.52 5.04 12.59 11.75 14.27 5.87 6.71 6.71 7.55 2.52 13.43 15.11 5.87 8.39 3.36 7.55 8.39 13.43 2.52 8.39

10.07 7.55 8.39 10.91 9.23 4.20 6.71 13.43 11.75 11.75 10.91 6.71 0.00

1 8050000.00

8.39 15.95 35.25 21.82 22.66 19.30 26.86 12.59 17.62 31.89 21.82 20.98 17.62 26.86 15.11 23.50 16.78 30.21 29.37 22.66 22.66 16.78 22.66

15.95 23.50 5.87 22.66 13.43 25.18 19.30 26.86 17.62 6.71 11.75 20.14 19.30 23.50 14.27 27.69 21.82 20.98 9.23 20.14 64.62 17.62 23.50 8.39 15.11 15.11 21.82

6.71 20.98 29.37 24.34 20.98 16.78 17.62 11.75 25.18 26.86 24.34 20.98 21.82 15.11 0.00

1.37 6.08 14.32 7.01 11.00 7.54 11.19 3.85 7.11 13.96 6.67 12.18 7.18 10.64 5.47 16.83 3.79 21.73 9.60 12.82 9.11 5.45 12.86 3.74 8.62

0.83 9.30 2.92 14.68 5.85 13.81 5.18 1.28 3.44 8.30 7.25 12.03 4.16 8.80 9.74 7.23 1.76 8.49 56.16 5.41 7.29 1.70 4.96 4.45 9.66 1.35

7.16 12.32 10.99 8.29 6.38 6.61 2.07 8.25 13.16 8.23 8.70 8.71 4.44 0.00

2.52 6.71 10.91 8.39 9.23 8.39 9.23 6.71 6.71 10.91 8.39 9.23 8.39 9.23 5.87 11.75 5.04 12.59 9.23 10.91 7.55 5.87 11.75 5.87 8.39 2.52

7.55 5.87 9.23 6.71 11.75 6.71 3.36 4.20 7.55 7.55 10.07 5.87 9.23 7.55 7.55 3.36 7.55 28.53 7.55 8.39 3.36 5.87 5.87 9.23 3.36 9.23 9.23

7.55 6.71 7.55 7.55 4.20 9.23 11.75 7.55 8.39 8.39 7.55 0.00

This example contains the first 2 epochs from an artifact scan.


65 0 0

This line shows the number of EEG (65), MAG and GRA channels.


0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0 0 8 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0 0 0 0 0 0

This line shows the badness of the channels. One channel has badness 8, which stands for gradient and integral criterion.


2 1 2

This line states the number of conditions in the artifact scan list, and their indices: There are 2 conditions; the list element 0 contains condition 1, list element 1 contains condition 2. Condition 0 is not part of the scan.


0.000000 319120000.000000

A range from 0 – 319.120 seconds was scanned. The next lines give the values for the epochs in groups of 4:


0 7700000.00

This entry has artifact list index 0 (which corresponds to condition index 1, see above), and the position of the epoch is 7.700000 seconds.


The next 3 lines hold amplitudes, variances, and gradients for each channel.