== How do I import digitized electrode coordinates and head surface points ==
 
== How do I import digitized electrode coordinates and head surface points ==
 
Digitized electrode locations can be provided in a surface point file (extension *.sfp) in ASCII format. It is recommended that the first three digitized coordinates are the fiducials (fiduciary points), labeled ‘FidT9’, ‘FidT10′, FidNz’, followed by electrodes, and possibly additional skin points. A detailed description of the file and how to import it is given in the BESA help files (chapter: Working with Electrodes and Surface Locations).
 
Digitized electrode locations can be provided in a surface point file (extension *.sfp) in ASCII format. It is recommended that the first three digitized coordinates are the fiducials (fiduciary points), labeled ‘FidT9’, ‘FidT10′, FidNz’, followed by electrodes, and possibly additional skin points. A detailed description of the file and how to import it is given in the BESA help files (chapter: Working with Electrodes and Surface Locations).
Line 22: Line 28:
  
 
== How do I check the result ==
 
== How do I check the result ==
You can check on the correct reading of the file using the View Head Surface points window (menu "File → Head Surface Points and Sensors → View" or 'V' on the keyboard). See also the article [[Verifiy_Electrode_Coordinates]].
+
You can check on the correct reading of the file using the View Head Surface points window (menu "File → Head Surface Points and Sensors → View" or 'V' on the keyboard). See also the article [[Verify_Electrode_Coordinates]].
  
 
[[File:Digitized head surface points dialog.png|left|600px]]
 
[[File:Digitized head surface points dialog.png|left|600px]]
  
 
[[Category:Preprocessing]]
 
[[Category:Preprocessing]]

Revision as of 13:31, 12 May 2016

Module information
Modules BESA Research Basic or higher
Version 5.2 or higher

How do I import digitized electrode coordinates and head surface points

Digitized electrode locations can be provided in a surface point file (extension *.sfp) in ASCII format. It is recommended that the first three digitized coordinates are the fiducials (fiduciary points), labeled ‘FidT9’, ‘FidT10′, FidNz’, followed by electrodes, and possibly additional skin points. A detailed description of the file and how to import it is given in the BESA help files (chapter: Working with Electrodes and Surface Locations). An example sfp file could look like this:

FidNz -10.89 0.04 -4.30

FidT9 -0.61 -7.78 -5.24

FidT10 -0.70 7.34 -5.86

E1 -1.52 -2.31 6.98

E2 -1.65 -7.67 2.54

E3 -4.26 -8.31 -3.86

...

The file is read in using the dialog "Channel and digitized head surface point information" in menu "File → Head Surface Points and Sensors → Load Coordinate Files" (use 'CTRL-L' key on the keyboard).

How do I check the result

You can check on the correct reading of the file using the View Head Surface points window (menu "File → Head Surface Points and Sensors → View" or 'V' on the keyboard). See also the article Verify_Electrode_Coordinates.

Digitized head surface points dialog.png