Difference between revisions of "Event File Format"

From BESA® Wiki
Jump to: navigation, search
m (Added extra level 2 header to push the contents box to the top of the page.)
m
 
(7 intermediate revisions by 4 users not shown)
Line 2: Line 2:
 
|title = Module information
 
|title = Module information
 
|module = BESA Research Basic or higher
 
|module = BESA Research Basic or higher
|version = 5.2 or higher
+
|version = BESA Research 5.2 or higher
 
}}
 
}}
  
== Overview ==
+
=== Overview ===
 +
 
 
Event files (extension *.evt) contain triggers and events and can be loaded as an additional file to provide more information about the whole course of an EEG/MEG recording.
 
Event files (extension *.evt) contain triggers and events and can be loaded as an additional file to provide more information about the whole course of an EEG/MEG recording.
 
An event file can be edited by opening it in any text editor, e.g. Notepad. It is also possible to create new event files from scratch which can be imported into the data file later.  
 
An event file can be edited by opening it in any text editor, e.g. Notepad. It is also possible to create new event files from scratch which can be imported into the data file later.  
Line 13: Line 14:
  
 
=== File Header ===
 
=== File Header ===
The header is comprised of abbreviated descriptions for each column. Each entry in the data line must be specified in the header line at the correct column position. The order of the data elements and their description in the header line can be chosen arbitrarily and the entries can be separated by commas, tabs and/or spaces. The last n data elements can be omitted, if they are neither Code nor one of ''Tms'', ''Tmu'' or ''Tsec''. The following codes are recognized by the ERP module:
+
 
 +
The header is comprised of abbreviated descriptions for each column. Each entry in the data line must be specified in the header line at the correct column position. The order of the data elements and their description in the header line can be chosen arbitrarily and the entries can be separated by commas, tabs and/or spaces. The Code and one of ''Tms'', ''Tmu'' or ''Tsec'' are obligatory, other data elements can be omitted. The following codes are recognized by the ERP module:
 
* ''Code'' - event code (integer, see section [[#Event Codes|Event Codes]])
 
* ''Code'' - event code (integer, see section [[#Event Codes|Event Codes]])
 
* ''Tms'' - event time in milliseconds relative to the start of the data file or ''Tmu'' [in microseconds] or ''Tsec'' [in sec] (floating point value)
 
* ''Tms'' - event time in milliseconds relative to the start of the data file or ''Tmu'' [in microseconds] or ''Tsec'' [in sec] (floating point value)
Line 23: Line 25:
  
 
=== Event Codes ===
 
=== Event Codes ===
 +
 
The event code Code must be one of the following integers:
 
The event code Code must be one of the following integers:
  
Line 71: Line 74:
 
| Average segment
 
| Average segment
 
|}
 
|}
 +
  
 
=== Additional Event Information ===
 
=== Additional Event Information ===
 +
 
The event reaction time, event reaction code and event comment are represented by the comment in the main module as "''Comment (Rx,T____)''", where ''Comment'' is the event comment, ''x'' describes the reaction code and the underscored line will be filled with the reaction time. Reaction time and reaction code are only read if the event code specifies it as a trigger.
 
The event reaction time, event reaction code and event comment are represented by the comment in the main module as "''Comment (Rx,T____)''", where ''Comment'' is the event comment, ''x'' describes the reaction code and the underscored line will be filled with the reaction time. Reaction time and reaction code are only read if the event code specifies it as a trigger.
A "New Segment" event can include time information that defines the starting time of the segment. This is defined in the ''TriNo'' column of the event file. The format is YYYY-MM-DDTHH:MM:SS, e.g. 2010-04-26T15:30:20.31 (note: seconds are a decimal number). If no time is defined, use a hyphen ('-'). See [[#Examples|below]]) for an example.
+
A "New Segment" event can include time information that defines the starting time of the segment. This is defined in the ''TriNo'' column of the event file. The format is YYYY-MM-DDTHH:MM:SS, e.g. 2010-04-26T15:30:20.31 (note: seconds are a decimal number). If no time is defined, use a hyphen ('-'). See [[#Examples|Examples]] below.
 
An "Average Segment" includes the prestimulus baseline interval in microseconds. This is defined in the ''TriNo'' column of the event file.
 
An "Average Segment" includes the prestimulus baseline interval in microseconds. This is defined in the ''TriNo'' column of the event file.
  
 
=== Requirements ===
 
=== Requirements ===
 +
 
The file is valid if the header line contains at least the entries Code and one of ''Tms'', ''Tmu'' and ''Tsec''. The header specifications are case insensitive.
 
The file is valid if the header line contains at least the entries Code and one of ''Tms'', ''Tmu'' and ''Tsec''. The header specifications are case insensitive.
 
The file is invalid, if
 
The file is invalid, if
there are ambiguities in the header  
+
* there are ambiguities in the header  
there is a data type mismatch in the data line  
+
* there is a data type mismatch in the data line  
an event time specifies an event which happened later than the end of the acquisition
+
* an event time specifies an event which happened later than the end of the acquisition
 
Each omitted data entry is set to 0 or empty string by default.
 
Each omitted data entry is set to 0 or empty string by default.
 
A line with an invalid or unknown event code ''Code'' is skipped.
 
A line with an invalid or unknown event code ''Code'' is skipped.
  
 
=== Examples ===
 
=== Examples ===
Here are a couple of typical examples:<br>
+
 
'''1.) Simple trigger file'''
+
Here are a couple of typical examples:
 +
 
 +
'''1) Simple trigger file'''
 
{| style="border-spacing: 2px; border: 0px white;"
 
{| style="border-spacing: 2px; border: 0px white;"
 
| Tms
 
| Tms
Line 128: Line 136:
 
This example event file can be downloaded here: [[Media:EventFileExample1.evt|Example 1]]
 
This example event file can be downloaded here: [[Media:EventFileExample1.evt|Example 1]]
  
'''2.) Trigger file with reaction code and reaction time'''
+
'''2) Trigger file with reaction code and reaction time'''
 
{| style="border-spacing: 2px; border: 0px white;"
 
{| style="border-spacing: 2px; border: 0px white;"
 
| Tms
 
| Tms
Line 175: Line 183:
 
This example event file can be downloaded here: [[Media:EventFileExample2.evt|Example 2]]
 
This example event file can be downloaded here: [[Media:EventFileExample2.evt|Example 2]]
  
'''3.) Event file without triggers'''
+
'''3) Event file without triggers'''
 
{| style="border-spacing: 2px; border: 0px white;"
 
{| style="border-spacing: 2px; border: 0px white;"
 
| Tmu
 
| Tmu
Line 212: Line 220:
 
This example event file can be downloaded here: [[Media:EventFileExample3.evt|Example 3]]
 
This example event file can be downloaded here: [[Media:EventFileExample3.evt|Example 3]]
  
'''4.) File including triggers and events'''
+
'''4) File including triggers and events'''
 
{| style="border-spacing: 2px; border: 0px white;"
 
{| style="border-spacing: 2px; border: 0px white;"
 
| Tms
 
| Tms
Line 273: Line 281:
 
This example event file can be downloaded here: [[Media:EventFileExample4.evt|Example 4]]
 
This example event file can be downloaded here: [[Media:EventFileExample4.evt|Example 4]]
  
'''5.) New Segments'''
+
'''5) New Segments'''
 
{| style="border-spacing: 2px; border: 0px white;"
 
{| style="border-spacing: 2px; border: 0px white;"
 
| Tms
 
| Tms
Line 296: Line 304:
 
This example event file can be downloaded here: [[Media:EventFileExample5.evt|Example 5]]
 
This example event file can be downloaded here: [[Media:EventFileExample5.evt|Example 5]]
  
'''6.) Average Segments'''
+
'''6) Average Segments'''
 
{| style="border-spacing: 2px; border: 0px white;"
 
{| style="border-spacing: 2px; border: 0px white;"
 
| Tms
 
| Tms
Line 315: Line 323:
  
 
The file contains two average segments. The first, with a prestimulus interval of 100 ms, has a duration of 1100 ms. The second, with a prestimulus interval of 200 ms, has a length up to the end of the data file.
 
The file contains two average segments. The first, with a prestimulus interval of 100 ms, has a duration of 1100 ms. The second, with a prestimulus interval of 200 ms, has a length up to the end of the data file.
1
+
 
 
This example event file can be downloaded here: [[Media:EventFileExample6.evt|Example 6]]
 
This example event file can be downloaded here: [[Media:EventFileExample6.evt|Example 6]]
  
[[Category:ERP/ERF]]
+
[[Category:ERP/ERF]] [[Category:Data Import/Export]]

Latest revision as of 15:05, 5 May 2021

Module information
Modules BESA Research Basic or higher
Version BESA Research 5.2 or higher

Overview

Event files (extension *.evt) contain triggers and events and can be loaded as an additional file to provide more information about the whole course of an EEG/MEG recording. An event file can be edited by opening it in any text editor, e.g. Notepad. It is also possible to create new event files from scratch which can be imported into the data file later. Note the following conventions for event files:

  • Event descriptions are given in the columns of the event file
  • Each file must contain a header line and data lines

File Header

The header is comprised of abbreviated descriptions for each column. Each entry in the data line must be specified in the header line at the correct column position. The order of the data elements and their description in the header line can be chosen arbitrarily and the entries can be separated by commas, tabs and/or spaces. The Code and one of Tms, Tmu or Tsec are obligatory, other data elements can be omitted. The following codes are recognized by the ERP module:

  • Code - event code (integer, see section Event Codes)
  • Tms - event time in milliseconds relative to the start of the data file or Tmu [in microseconds] or Tsec [in sec] (floating point value)
  • TriNo - trigger number (integer) (identifies the trigger in the event bar of the main module)
  • RCode - reaction code (integer)
  • RTms - reaction time in milliseconds or RTmu or RTsec (floating point value)
  • Comnt - comment to describe event (string of up to 39 characters), will be truncated if longer than 39 characters.

You can also define columns which should not be recognized by the ERP module. Simply specify these columns in the header with any unknown code. Therefore you might be able to use previously generated files without major changes.

Event Codes

The event code Code must be one of the following integers:

Code Event/Trigger Type
1 Trigger
2 Comment
3 Marker
11 Pattern1
12 Pattern2
13 Pattern3
14 Pattern4
15 Pattern5
21 Artifact on
22 Artifact off
31 Epoch on
32 Epoch off
41 New segment
42 Average segment


Additional Event Information

The event reaction time, event reaction code and event comment are represented by the comment in the main module as "Comment (Rx,T____)", where Comment is the event comment, x describes the reaction code and the underscored line will be filled with the reaction time. Reaction time and reaction code are only read if the event code specifies it as a trigger. A "New Segment" event can include time information that defines the starting time of the segment. This is defined in the TriNo column of the event file. The format is YYYY-MM-DDTHH:MM:SS, e.g. 2010-04-26T15:30:20.31 (note: seconds are a decimal number). If no time is defined, use a hyphen ('-'). See Examples below. An "Average Segment" includes the prestimulus baseline interval in microseconds. This is defined in the TriNo column of the event file.

Requirements

The file is valid if the header line contains at least the entries Code and one of Tms, Tmu and Tsec. The header specifications are case insensitive. The file is invalid, if

  • there are ambiguities in the header
  • there is a data type mismatch in the data line
  • an event time specifies an event which happened later than the end of the acquisition

Each omitted data entry is set to 0 or empty string by default. A line with an invalid or unknown event code Code is skipped.

Examples

Here are a couple of typical examples:

1) Simple trigger file

Tms Code TriNo Comnt
100.234 1 3 Trigger: 3
2300.456 1 1 Trigger:1
4500.21 1 1 Trigger:1
9800.47 1 7 Trigger:7
12500.78 1 2 Trigger:2
21237 1 1 Trigger:1

This example event file can be downloaded here: Example 1

2) Trigger file with reaction code and reaction time

Tms Code TriNo RTsec RCode
100.234 1 3 0.23 1
2300.456 1 1 1.11 2
4500.21 1 1 0.15 1
9800.47 1 7 0.87 0
12500.78 1 2 2.1 2
21237 1 1 3 1

This example event file can be downloaded here: Example 2

3) Event file without triggers

Tmu Code Comnt
10000.234 3 Marker
230000.456 12
450000.21 14
980000.47 12
1250000.78 3 Marker
2123700 2 Comment
2534100.567 15

This example event file can be downloaded here: Example 3

4) File including triggers and events

Tms Code TriNo RTsec RCode Comnt
100.234 2 0 0 0 CommentSet
2300.456 1 2
4500.21 1 1 0.15 1
9800.47 11
12500.78 3
21237 2 0 3 1 Comment
25341.567 15

This example event file can be downloaded here: Example 4

5) New Segments

Tms Code TriNo Comnt
0 41 2010-04-26T15:30:20.31 Start recording
21000 41 2010-04-27T09:17:00.0 Next day

The new segment at the time 0 overrides the start time in the file. A second segment at 21 s starts a new data block one day later at 9:17.

This example event file can be downloaded here: Example 5

6) Average Segments

Tms Code TriNo Comnt
0 42 100000 Cond 1: 25 avs
1100 42 200000 Cond 2: 201 avs

The file contains two average segments. The first, with a prestimulus interval of 100 ms, has a duration of 1100 ms. The second, with a prestimulus interval of 200 ms, has a length up to the end of the data file.

This example event file can be downloaded here: Example 6